Download Brochurer!
Gazellvirksomhed i 2009
AAA Rating
Forside arrow Produkter arrow Komfortventilatorer arrow Kontor og let industri arrow Powerflow In-Line Duct fans

Powerflow In-Line Duct fans

Powerflow In-Line Duct fans

Description

Powerflow models provide a compact yet versatile range designed with the installer in mind, combining the acoustic benefits of a tough plastic casing with the pressure characteristics of a centrifugal fan.

A range of eight models from 100 to 315mm dia. duct sizes. The 300mm dia. model has been specifically developed for use with rigid ductwork. Air volumes from 0.059m³/s to 0.42m³/s at free air and capable of pressure development up to 550 Pa.

Powerflow has 50-80mm long inlet and discharge spigots allowing easy installation and fixing. The adjustable mounting foot allows the terminal box to be rotated to any angle and allows plenty of space and adjustment for screw fixing. The robust fire retardant polymeric casing combined with outlet guide vanes ensures optimum airflow management through the unit.

Electrical

Motors are single phase 220-240V single phase 50Hz. Capacitor start and run. An IP54 terminal box is supplied with all models with PG16 entry and the capacitor is conveniently located in the terminal box. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.).

Typical Installation


Powerflow typical installation
A. Pre-filter 85% arrestance. Removes dust etc, from fresh supply air.
B. Robust polymeric casing minimises noise breakout levels into the room area.
C. Flexible ducting lightweight and easy to install.Conforms to Class I of BS476 Part 7.
D. Duct attenuator can reduce NC/NR levels.
E. Anti-vibration mount
F. CEILING

Motor / Impeller

All models are fitted with an external rotor motor and backward curved impeller assembly for long life and reliability.

Sizes 100 and 125 are protected to IP54, all other sizes are IP44 according to BS 5490 (IEC 529) and IEC 34-5. Ball bearings are greased for life and designed to run at any angle. Insulation is Class 'B'
(from -30°C to +40°C). Manufacture is controlled to BS EN ISO 9001.

Electronic Controller

2.5Amp electronic controller.
Surface mounting
Provides infinitely variable speed control and features an On/Off/sensor slider with neon indicator. Adjustable minimum speed setting. Electrical connections for use with suitable external sensors are provided.
86 x 156 x 53mm (HxWxD).
Hole for wall box:
80 x 150 x 50mm (H x W x D).
Stock Ref. No. W103 03 102M

Dimensions (mm)

Powerflow dimensions

Size Øa b c d e Øf g h kg
ACP100-12A 99 145 280 50 50 254 87 60 2.2
ACP125-12A 124 147 280 50 50 254 87 70 2.2
ACP150-12A 149 169 293 50 50 301 87 80 2.2
ACP200-12A 199 186 288 60 60 342 87 100 4.3
ACP250-12A 249 198 305 60 60 366 87 100 4.6
ACP315-12A
ACP315-12/H
314 218 362 60 80 406 121 120 5.9
6.1

Technical Data


Dia. 100 125 150 200 250 315 315
Stock Ref. No. ACP100-12A ACP125-12A ACP150-12A ACP200-12A ACP250-12A ACP315-12A ACP315-12/H
RPM 2470 2410 2520 2620 2720 2720 2667
Watts 83 86 100 150 185 182 300
S.C. Amps 0.85 0.85 1.10 1.52 1.60 1.57 4.00
F.L.C. Amps 0.34 0.34 0.43 0.68 0.77 0.75 1.30
dB(A) @ 3m 35 35 45 47 48 51 52
Flexible Ducting 105 39 100 105 39 125 105 39 150 105 39 200 105 39 250 105 39 315 105 39 315
Supply Diffusers 105 43 100 105 43 125 105 43 150 105 47 200
+ 105 46 230
105 47 250
+ 105 46 300
105 47 300
+ 105 46 350
105 47 300
+ 105 46 350
Exhaust Diffusers 105 44 100 105 44 125 105 44 150 105 44 200 56 06 40
+ 56 08 49
56 06 42
+ 56 08 49
Louvre Shutter 105 01 100 105 01 125 105 01 150 105 01 200 105 01 250 105 01 315 105 01 315
Backdraught Shutters 105 42 100 105 42 125 105 42 150 105 42 200 105 42 250 105 42 315 105 42 315
Wall Termination W105 54 150 W105 54 150 W105 54 150 W105 54 200 W105 54 250 W105 54 315 W105 54 315
Pre-filter Cassette Sets 105 32 100A 105 32 125A 105 32 150A 105 32 200A 105 32 250A 105 32 315A 105 32 315A
Figures are based on a 1 Phase Motor

Tough plastic in-line range in six models.
50-80mm long ribbed spigots.
Flame retardant casing.
All models speed controllable.
Fitted with Standard Thermal Overload Protection (S.T.O.P.).
For the best performance from your fan use a Vent-Axia controller.
DEMKO and LGA/GS Approved.

Powerflow In-Line Duct fanspiece