Forside Produkter Aksialventilatorer Plademonteret for vægmontage
|
Aksialventilator VSP
- One shot die cast impeller, dynamically balanced for smoother operation
- External Rotor Motors on all models for compact efficient design
- All models speed controllable and can be wired for reverse running
- Guards fitted as standard on all models
- Thermal Overload Protection for motor protection
- Maintenance free sealed for life bearings
- 2 Year Guarantee
Mere info... |
|
HC
Wall mounted axial fans- Sheet steel support frame.
- Polyamide 6 fibreglass- reinforced impeller; dynamically balanced in compliance with ISO 1940 standard.
- Asynchronous motors, with squirrel-cage rotor with ball bearings.
- IP-55 Protection (IP-54 models 45-4M/H, 50-4M/H, 50-6M/H,
- 56-4M/L, 56-6M/H, 63-4M/L and 63-6M/H).
- Class F insulation. Standard models can operate at temperatures between -25° C +60° C.
- Standard models supplied with three-phase 230/400V, 50 Hz up to 5.5 HP, and 400/690V, 50 Hz for more powerful units.
- Single-phase 230V, 50 Hz motors.
- Motor support including protection guard according to 24167 DIN and 20-359-74 UNE standards, except in models 71, 80, 90 and 100 where the guard can be ordered as an accessory.
- Anticorrosive finish in polyester resin, polymerised at 180°C, after degreasing, phosphating and passivation pre-treatment.
- Windings can be supplied on request for 230/400 V, 60 Hz; 254-280/ 440-480 V, 60 Hz.
Mere info... |
|
HCD
Wall-mounted axial fans- Rolled sheet steel support frame.
- Aluminium sheet impeller.
- Motor for models 20,25,30 and 35:
- Single-phase, four-pole shading ring 230V, closed construction, IP-44 insulation, class B self-protecting and self-lubricated.
- Working temperature: -30°C +50°C.
- Motor model 40.
- Single-phase, asynchronous motor with squirrel-cage rotor and ball bearings, 230V.
- IP-54 class F protection.
- Class F insulation.
- Standard model can operate at temperatures between -25°C + 60°C.
- Anticorrosive finish in polyester resin, polymerised at 180°C, after degreasing, phosphating and passivation pre-treatment.
Mere info... |
|
HCDF
Flame-resistant axial fans- Aluminium sheet frame (to avoid sparks).
- Cast aluminium impeller (to avoid sparks).
- 230/400 V 50Hz (EEx-d) II BT4 motor in compliance with standard EN 50014 and EN 50018, officially ATEX approved.
- IP-55 protection and class F insulation.
- Anticorrosive finish in polyester resin, polymerised at 180°C, after degreasing, phosphating and passivation pre-treatment.
- Stuffing-box included.
- On request the following can be supplied:
- CE Mark Ex II 2 D Eex D
- Tubular execution (HDF)
Mere info... |
|
HCH
Axial fans- Rolled sheet steel casing.
- IP-55 protected external connection box (HCT).
- Impeller: variable pitch blades, which can be supplied in 2 versions:
- Version PL: reinforced fibreglass polyamide 6 hub and blades (Aluminium hub in models 80, 90 and 100).
- Version AL: aluminium cast impellers.
- HCT-40-2T and HCT-45-2T only available in aluminium.
- Standard motors 230/400V, 50 Hz up to 5.5 HP, and 400/690V, 50 Hz for more powerful units; single-phase 230V, 50 Hz motors
- IP-55, class F protection (IP-54 models 45-4M-0.5 and 56-4M-0.75)
- Anticorrosive finish in polyester resin, polymerised at 180°C, after degreasing, phosphating and passivation pre-treatment.
On request:- Impellers with impeller to motor airflow direction.
- 100% reversible impellers
- Category 2 ATEX certification for explosive atmospheres and CE Mark Ex II 2 G/D Eex E or D.
Mere info... |
|
HCH-40C
Axial fans- Rolled sheet steel casing.
- IP-55 protected external connection box (HCT).
- Impeller: variable pitch blades, which can be supplied in 2 versions:
- AL Versions with impellers in cast aluminium.
- Standardised motors 230/400 V, 50 Hz, and single-phase 230V IP-55 protection, class F insulation. (IP-54 models 45-4M-0.5 and 56-4M-0.75)
- Epoxy resin powder, zinc-phosphated and kiln dried at 200°C.
- On request:
- Impellers with impeller to motor air-flow direction.
- 100% reversible impellers
- Explosion and fireproof two speed motors.
Mere info... |
|
HCH-SEC
Axial fans- Rolled sheet steel casing.
- IP-55 protected external connection box (HCT).
- Impeller: variable pitch blades, which can be supplied in 2 versions:
- Version PL: reinforced fibreglass polyamide 6 hub and blades (Aluminium hub in models 80, 90 and 100).
- Version AL: aluminium cast impellers.
- HCT-40-2T and HCT-45-2T models only available in aluminium.
- Standardised motors 230/400 V, 50 Hz and single-phase 230V 50 Hz.
- IP-55 protection and class F insulation (IP-54 models 45-4M-0.5 and 56-4M-0.75).
- Epoxy resin powder, zinc-phosphated and kiln dried at 200°C.
- On request:
- Impellers with impeller to motor airflow direction.
- 100% reversible impellers
- Explosion and fireproof two speed motors.
Mere info... |
|
HCT-40C
Axial fans- Rolled sheet steel casing.
- IP-55 protected external connection box (HCT).
- Impeller: variable pitch blades, which can be supplied in 2 versions:
- Version AL: aluminium cast impellers.
- HCT-40-2T and HCT-45-2T only available in aluminium.
- Standardised motors 230/400 V, 50 Hz, and single-phase 230V 50 Hz.
- Class F insulation and IP-55 protection. (IP-54 models 45-4M-0.5 and 56-4M-0.75)
- Epoxy resin powder finish, zinc-phosphated and kiln dried at 200°C.
- On request:
- Impellers with air-flow direction: impeller to motor.
- 100% Reversible impellers
- Explosion and fireproof two speed motors.
Mere info... |
|
HCT-MAR
Axial fans- Rolled sheet steel casing.
- IP-55 protected external connection box (HCT).
- Impeller: variable pitch blades, which can be supplied in 2 versions:
- Version AL: cast aluminium impellers.
- HCT-40-2T and HCT-45-2T only available in aluminium.
- Epoxy resin powder, zinc-phosphated and kiln dried at 200°C.
- On request:
- Aspiration impellers with impeller to motor airflow direction.
- 100% reversible impellers
- Explosion and fireproof two speed motors.
Mere info... |
|
HDF
Flame-resistant axial fans- Sheet steel housing with internal aluminium ring (to avoid sparks).
- Cast aluminium impeller (to avoid sparks).
- 230/400 V 50Hz (EEx-d) II BT4 motor in compliance with standard EN 50014 and EN 50018, officially ATEX approved.
- IP-55 protection and class F insulation.
- Anticorrosive finish in polyester resin, polymerised at 180°C, after degreasing, phosphating and passivation pre-treatment.
- Stuffing-box included.
- On request the following can be supplied:
- CE Mark Ex II 2 D Eex D
- Long cased version (HDF).
Mere info... |
|
HEP
Axial fans Fan: - Sheet steel support frame.
- Rolled steel-sheet long housing. (HEPT).
- External connection box, IP-65 protection. (HEPT).
- Motor support with safety guard, in compliance with DIN 24167 and UNE 20-359-74 standards.
- Polyamide 6 fibreglass-reinforced impeller; dynamically balanced in compliance with ISO 1940 standard.
- Anticorrosive finish in polyester resin, polymerised at 180°C, after degreasing, phosphating and passivation pre-treatment.
- Supplied with connection box or without box on demand. (HEP)
Motor:- Asynchronous motors, with squirrel-cage rotor.
- Standard motors supplied with three-phase 220-240/380-415 V 50 Hz and single-phase 220-240 V, 50 Hz motor.
- Class F insulation and IP65 protection.
- Standard models can operate at temperatures between -25°C +60°C 4-6 and 8 Pole motors, and -25°C +45°C 2 pole motors.
Thermal protection- All motors are fitted with thermal protection (Klixon) to avoid overheating produced by any type of anomaly.
Mere info... |
|
HGI
Large-diameter axial fan- Axial fan designed to move large volumes of air at low speed, with low noise level and easy maintenance.
- Low output power unit, particularly suitable for poultry and livestock farms, greenhouses, drying rooms, industrial facilities, sports centres, etc.
- Housing made entirely of anticorrosive galvanized sheet metal.
- Standardised 230-400V, 50 Hz and 254-280/400-480V. 60 Hz motors, easily exchangeable.
- Class F electrical insulation.
- IP-54 protection.
- Galvanized sheet steel impeller.
- Galvanized safety guard.
- Supplied with backdraught louvre made of galvanized steel with automatic opening system.
Mere info... |
|
HRE
Circular axial fans.- Frame in rolled sheet steel.
- Impeller in sheet steel.
- Asynchronous external rotor motors.
- Three-phase 230/400V, 50 Hz.
- Single-phase 230V, 50 Hz.
- Single-phase with thermal protection included, with automatic reset.
- Terminal box on the motors.
- Working temperature: -25°C +50°C
- Anticorrosive finish in polyester resin, polymerised at 180°C, after degreasing, phosphating and passivation pre-treatment.
Mere info... |
|
HSEC 135ºC
Axial fans- Ventilators specially designed for operation in ceramic and wooden driers, environments with maximum temperature of 135ºC and 100% humidity.
- Reinforced casing in 5754 aluminium and support motor in stainless steel X5CrNi18 F-3504.
- Variable paddle helix in cast aluminium, 100% reversible.
- 50 Hz three-phase motors. Class H insulation and IP-55 protection.
- Dynamically balanced in accordance with ISO-1940 Q6.3.
Mere info... |
|
HSEC 85ºC
Axial fans- Ventilators specially designed for operation in ceramic and wooden driers, environments with a maximum temperature of 85ºC and 100% humidity.
- Reinforced casing in stainless steel X5CrNi18 F-3504.
- Variable paddle helix in cast aluminium, 100% reversible.
- 50 Hz three-phase motors. Class F insulation and IP-55 protection.
- Dynamically balanced in accordance with ISO-1940 Q6.3.
Mere info... |
|
VAC
Axial fansFan: - Support frame in heat galvanized steel plate.
- Steel plate support arms.
- Support motor with contact protection grill, in accordance with standards DIN 24167 and UNE 20-359-74.
- Polyamide 6 helix reinforced with fibreglass; dynamically balanced in accordance with ISO standard 1940.
- Anti-corrosive finish specially designed for operation on farms.
Motor:- Asynchronous motors, with squirrel cage rotor.
- Standard series supplied with three-phase motor.
220-240/380-415 V 50 Hz and mono-phase 220-240 V, 50 Hz.- Class F insulation and IP-65 protection.
- The standard models can operate at temperature between:-25°C+70°C motors of 4-6-8 poles, and -25°C+ 45°C motors with 2 poles.
Thermal protection:- The entire range of motors is supplied with thermal protection (Klixon) included to protect the motor from overheating due to any anomaly.
Mere info... |
|
VAM
Axial fans Fan: - Sheet steel support frame.
- Motor support with safety guard, in compliance with DIN 24167 and UNE 20-359-74 standards.
- Polyamide 6 fibreglass-reinforced impeller; dynamically balanced in compliance with ISO 1940 standard.
- Anticorrosive finish especially designed for work on farms
Motor:- Asynchronous motors, with squirrel-cage rotor.
- Standard motors supplied with three-phase 220-240/380-415 V 50 Hz and single-phase 220-240 V, 50 Hz motor.
- Class F insulation and IP-65 protection.
- Standard models can operate at temperatures between -25°C +70°C 4-6 and 8 Pole motors, and -25°C +45°C 2 pole motors.
Thermal protection - All motors are fitted with thermal protection (Klixon) to avoid overheating produced by any type of anomaly.
Mere info... |
Resultater 1 - 17 af 17
|